120V Uninterruptible Power Supplies
Single Phase, On-Line 1 kVA, 2 kVA and 3 kVA
The Staco Energy Products Company is a leading manufacturer
of AC voltage control products and products that improve
power quality. Our expertise in providing solutions
to electrical power problems stems from over 60 years
of experience building standard as well as custom designed
products for both the military and private business
sectors.
The UniStar II "U" Series UPS is designed
to meet the power protection needs of sensitive electronic
equipment and computer loads while addressing the power
quality concerns of today. UPS reliability begins with
its design and over 25 years of application experience.
The UniStar II series UPS delivers true on-line power,
of high quality, with low distortion, and true sine-wave
output allowing the UPS to power any combination of
linear and non-linear loads. Being a true On-Line double
conversion design, the UniStar II provides regulated
output voltage and frequency and its input has been
power factor corrected and designed to reflect harmonics
of less than 6% THD back to the input system under
any load conditions. A wide voltage input range of
as low as 27% below and 10% above nominal reduces battery
discharge cycling while extending the battery life
and assuring that the battery backup power will be
available when needed.
Special circuitry has been incorporated into the UniStar
II "U" series UPS designed to protect and
lengthen the service life of the most sensitive component
of a UPS system ... its batteries. The UPS Micro processor
controller manages a variety of functions including
a battery management system that tracks battery charge
status preventing battery overcharging , self-diagnostic
testing, and the front panel display which reports
the status of the UPS ... On-Line, On-Battery, Bypass,
Overload, Low Battery, and System Fault.
The UniStar II available in 1 kVA, 2 kVA, and 3 kVA
ratings isolates the connected load from the AC input
supply, protecting the load from voltage sags, spikes,
surges , brownouts, blackouts, transients, RFI electrical
noise and frequency variations. In the event of AC
input supply failure, an internal audible alarm sounds
and the UPS will continue, without interruption, to
provide safe, clean continuous power from its sealed
batteries. When the AC input supply return s to normal,
the UPS returns to its double conversion operating
mode and automatically recharges the batteries for
the next power disturbance.
Protect your mission critical equipment with the best
- the new generation UniStar II "U" series
UPS. Extended run-time, output options, and custom
designs are a "Staco-Plus."
General Specifications |
| AC Input Characteristics |
| Voltage: |
120 VAC (88-138) |
| Frequency: |
50/60 HZ, auto-sensing |
| Power factor: |
> .97 |
| Harmonic Distortion: |
< 6% THD |
| |
| AC Output Characteristics |
| Voltage: |
120 VAC |
| Frequency: |
50/60 Hz ± 2 Hz, with a slew
rate of 1 Hz/sec |
Voltage Regulation
Steady State:
Dynamic: |
± 2%
± 5%, 100% load change |
| Harmonic Distortion: |
3% linear load
5% non-linear load |
| Overload Capacity: |
125% for 3 minutes
150% for 30 seconds |
| Full load PF: |
.7 |
| Crest Factor: |
3:1 |
| |
| Safety |
| Listed to UL 1778 |
| Compliance to CSA 22.2; TUV/GS |
Electromagnetic Immunity:
IEC 801-2 level IV, 801-4 level IV, 801-5 level III |
| EMC Verification: FCC Class A; CE;
TUV |
| |
| Options |
| Single/Multi-line phone protection |
| SNMP power management software |
| I/O configurations |
| Extended battery runtime |
| Hard wired input/output |
| |
| System Characteristics |
| Efficiency: |
80% to 85% |
Surge Protection
Energy rating:
Current capability:
Voltage let through:
Response time: |
480J (10/1000,s waveform)
6500A (8/20,s waveform)
<0.3% of peak
0 ns normal mode
<5ns common mode |
Battery System
Runtime:
Typical recharge:
Typical life: |
See below
2 to 4 hours, 50% discharge
3 to 5 years |
| Communication ports: |
2-female DB-9 |
| Audible noise: |
<45 dBA |
| |
| Environmental |
| Ambient Temperature: |
0° to 40° C |
| Relative Humidity: |
0 to 95% non-condensing |
| Operating Altitude: |
0 to 10,000 ft. |
| Storage Temperature: |
-15° to +45° C |
| |
| Controls, Status and Alarms |
| Input Circuit Protector |
| Output Circuit Breaker |
| LED indicators: On line, On Battery,
Bypass, Overload, Battery Low, and Fault |
| |
Battery Runtime |
%FL
(minutes) |
1
kVA |
2
kVA |
3
kVA |
| 50 |
75 |
100 |
50 |
75 |
100 |
50 |
75 |
100 |
| Internal |
31 |
18 |
12 |
21 |
12 |
7 |
18 |
10 |
6 |
| External |
1-UBP2 |
N/A |
N/A |
N/A |
65 |
37 |
24 |
- |
- |
- |
| 2-UBP2 |
134 |
78 |
54 |
- |
- |
- |
| 3-UBP2 |
- |
- |
- |
55 |
30 |
18 |
| 4-UBP2 |
- |
- |
- |
115 |
67 |
46 |
|
|